Product Specification
On Load Tap Changer Power Transformer
The On Load Tap-Changer Power Transformer widely applies to urban and rural electric network construction. The iron core is in ladder shape and changes the traditional piling way of iron core as well as the inner distribution of magnetic way. It also decreases the no-load consumption, no-load current consumption and noise pollution all by 20%. The load consumption also decreases by 10%. The new product applies CAD tool and marked with advanced design, reasonable structure, and high quality material.
Features
Reliable and advanced performance.
The iron core applies three junctions painted with solid paint on the surface to lessen consumption and noise pollution.
Original winding structure and scientific designed oil channel. The new structure improves mechanical capability and short-circuit resistance.
The oil tank has various forms with aesthetic appearance.
Technical Specification
Capacity
(kVA)
Voltage Schedule
Linkage No.
(%)
Consumption
Short Circuit
Impedance (%)
No Load
Current (%)
Outline Dimension
mm (+-10%)
Weight
KG(+-10%)
Gauge
(mm)
HV (kV)
LV (kV)
No Load
(kW)
Load
(kW)
Length
Width
Height
Oil
Total
200
6
0.44
3.25
4
1.8
1400
1120
1650
420
1550
550
250
6.3
0.53
3.7
1.7
1420
1130
1690
435
1600
550
315
10
0.63
4.41
1.6
1530
1200
1760
475
1630
660
400
10.5
0.75
5.4
1.5
1630
1210
1850
505
2030
660
500
11
Y, yn0
0.88
6.45
1.4
1640
1230
1890
550
2110
660
630
+-4
0.433
1.12
7.65
4.5
1.3
1660
1350
1960
625
2670
660
800
x 2.5%
1.36
9.35
1.2
2600
1600
2750
1120
4240
820
1000
1.6
11
1.1
2630
1700
2730
1055
4490
820
1250
1.87
13.05
1
2660
1820
2780
1280
5150
820
1600
2.4
15.6
0.9
2720
1680
2970
1380
6210
1070
2000
2.9
18.5
0.8
2800
2230
2980
1420
6530
1070
800
35
1.32
10.5
1.3
2870
1810
2570
1650
4790
1070
1000
38.5
1.57
12.8
1.2
3150
1890
2650
1760
5210
1070
1250
+-3
1.86
15.4
1.1
3510
2040
2690
2010
6080
1070
1600
x 2.5%
2.25
18.5
1.1
3560
2070
2740
1920
6610
1070
2000
2.89
20.3
6.15
3680
2050
2850
2160
7440
1070
2500
Y, d11
3.4
21.7
1
3780
2220
2890
2580
8240
1070
Note: Dimensions and weights etc, given above are just indicative. We reserve our right for constant improvement/modifications.
Standard Fittings
Conservator
Silicagel Breather
Off Circuit Top Changer
Oil Level Gauge
HV Bushing
LV Bushing
Air Release Plug
Lifting Lugs
Rating & Diagram Plates
Radiators
Base Channel with Rollers
Earthing Terminals
Explosion Vent.
Note:
Transformers with other Voltage Ratio, Vector Group, Terminal arrangement can be supplied as per the customers requirement. Fittings like Cable end box, Gas operated
relay, MOG, Marshalling box can be provided as per the requirement. Transformers with lower No Load Losses and Load Losses can also be supplied.
Other Products in 'Transformers' category
Completely Sealed Distribution Transformer
Oil Immersed Power & Distribution Transformer
Wound Core Type Oil Immersed Distribution
Oil Immersed Power & Distribution Transformer
Dry Type (Air Cooled) Transformer with Varnish
Amorphous Metal Distribution Transformer
<< Back
Contact Details
5 km stone malout road,Bathinda - 151002, Punjab, India
Phone:
91-164-2270407
Fax:
91-164-2237887/2270407
Send Mail
Contact Now
Send E-mail
Key Personnel
Mr. Pankaj Agarwal (Director)
Mobile:
+919216332387, +919815332387
Copyright © 2009 by JAYBEE INDUSTRIES All Rights Reserved.